Need assistance with selecting the correct solution to meet your specific requirements?
To see the Mobile Pipeline Blowdown and Cross Compression Solutions Brochure
BAUER C52.7 X-Fill PERFORMANCE (EACH SIMPLEX COMPRESSOR SYSTEM)
Compressor Inlet Pressure | Compressor Outlet Pressure | Compressor | Actual Used Power | Flow Rate | Combined Flow Rate |
---|---|---|---|---|---|
PSIG | PSIG | RPM | HP | SCFM | MMFCD |
145 | 1450 | 1425 | 293 | 867 | 1.25 |
110 | 1450 | 1425 | 249 | 668 | 0.96 |
90 | 1450 | 1425 | 230 | 496 | 0.71 |
60 | 1450 | 1425 | 185 | 286 | 0.56 |
Note: 1) All performance data for compressed gas inlet (suction conditions) is stated at Standard Conditions: Suction Pressure as Indicated, Gas Temperature of 68⁰ F (20⁰C), and RH of 0% 2) All performance data for the compressed gas outlet is stated at ISO 1217 Reference Conditions: Absolute Pressure at 364 ft (111m) elevation = 14.5 PSIG ( 1 Bar), Gas Temperature of 68⁰ F (20⁰C) and RH of 0% 3) All performance data are based on a typical well gas composition based on the following Mol percentages: Methane 97%, Nitrogen 1.0%, Carbon Dioxide 2%