SYSTEM FOOTPRINT
DIMENSIONS L X W X H inches (mm)
- 51” x 64” x 85” (1295.4 mm x 1625.6 mm x 2159 mm)
BAUER GRU® 3 Performance At Various Horsepower and Suction Pressure Combinations | |||||||
---|---|---|---|---|---|---|---|
Motor | Suction Pressure | Max Flow at 150 PSIG Discharge Pressure | Max Flow at 232 PSIG Discharge Pressure | ||||
hP | kW | PSIG | BAR | SCFM | M3/H | SCFM | M3/H |
BAUER GRU® 3 (15HP/11kW) | |||||||
15 | 11 | 1 | 0.069 | 43 | 73 | 32 | 54 |
15 | 11 | 5 | 0.34 | 50 | 84 | 36 | 61 |
15 | 11 | 10 | 0.7 | 58 | 99 | 41 | 70 |
BAUER GRU® 3 (20HP/15kW) | |||||||
20 | 15 | 1 | 0.069 | 55 | 93 | 43 | 73 |
20 | 15 | 5 | 0.34 | 68 | 115 | 50 | 85 |
20 | 15 | 10 | 0.7 | 78 | 132 | 59 | 100 |
BAUER GRU® 3 (25HP/18.5kW) | |||||||
25 | 18.5 | 1 | 0.069 | 63 | 10 | 54 | 91 |
25 | 18.5 | 5 | 0.34 | 80 | 136 | 66 | 112 |
25 | 18.5 | 10 | 0.7 | 104 | 176 | 75 | 127 |
All performance values referenced in the table above are based on the following conditions: Referenced to ISO 1217 (14.50 psi (100 kPA), 68°F (20°C), 0% RH), Biogas temperature at compressor inlet: 86°F (30°C). Biogas Composition: 52% CH4, 46% CO2, 1% N2, 1% O2. Discharge pressure at compressor skid edge. Any deviations from these conditions will modify the stated performance results. Consult with your Bauer representative for conditions other than referenced herein.