Need assistance with selecting the correct solution to meet your specific requirements?
To see the entire Biogas Brochure
SYSTEM FOOTPRINT
DIMENSIONS L X W X H inches (mm)
- 51” x 64” x 85” (1295.4mm x 1625.6mm x 2159mm)
BAUER GRU® 6 Performance At Various Horsepower and Suction Pressure Combinations | |||||||
---|---|---|---|---|---|---|---|
Motor | Suction Pressure | Max Flow at 150 PSIG Discharge Pressure | Max Flow at 232 PSIG Discharge Pressure | ||||
hP | kW | PSIG | BAR | SCFM | M3/H | SCFM | M3/H |
BAUER GRU® 6 (30HP/23kW) | |||||||
30 | 22 | 1 | 0.069 | 86 | 145 | 57 | 97 |
30 | 22 | 5 | 0.34 | 99 | 168 | 66 | 112 |
30 | 22 | 10 | 0.7 | 112 | 190 | 71 | 121 |
BAUER GRU® 6 (40HP/30kW) | |||||||
40 | 30 | 1 | 0.069 | 116 | 196 | 85 | 144 |
40 | 30 | 5 | 0.34 | 147 | 250 | 97 | 165 |
40 | 30 | 10 | 0.7 | 178 | 302 | 110 | 187 |
BAUER GRU® 6 (50HP/38kW) | |||||||
50 | 37 | 1 | 0.069 | 155 | 263 | 109 | 185 |
50 | 37 | 5 | 0.34 | 186 | 316 | 128 | 217 |
50 | 38 | 10 | 0.7 | 218 | 371 | 150 | 255 |
All performance values referenced in the table above are based on the following conditions: Referenced to ISO 1217 (14.50 psi (100 kPA), 68°F (20°C), 0% RH), Biogas temperature at compressor inlet: 86°F (30°C). Biogas Composition: 52% CH4, 46% CO2, 1% N2, 1% O2. Discharge pressure at compressor skid edge. Any deviations from these conditions will modify the stated performance results. Consult with your Bauer representative for conditions other than referenced herein.