mail-icon
Need assistance with selecting the correct solution to meet your specific requirements?

pdf-icon
To see the entire Helium Systems Catalog

SYSTEM FOOTPRINT

Enclosed Design Dimensions L x W x H inches (mm)

  • 133” x 104” x 115” (3378 mm x 2642 mm x 2921 mm)

Enclosed Design WEIGHT pounds (kg)

  • 10000 lbs (4535 kg) Approximately

For Open Design: contact us for weight, dimensions, and OD drawings

Technical Data

Model Max Inlet Pressure2 Capacity FGD1 RPM Number of Stages Motor Drive
  PSIG BAR SCFM M3/HR     HP KW  
UP TO 5000 PSIG OPERATING PRESSURE (ELEVATED INLET PRESSURE)2
GBHE23.10 29-65 4-45 37-69 64-117 1140 4 50-60 37-45 E3
GBHE23.12 65-130 4.5-9 48-85 82-144 1140 4 50-60 37-45 E3
GBHE23.13 116-203 8-14 59-99 101-168 1140 4 50-60 37-45 E3

1 Volume flow rate according to ISO 1217.  Valid for Helium. Contact BAUER for performance verification. Capacities referenced to atmospheric inlet pressure. Motor power valid for max. inlet and final pressure. Actual performance values may vary depending upon site conditions. 2 Lower inlet pressure can result in lower operating pressure. Contact BAUER for min. / max. operating pressure relative to inlet pressure.