Need assistance with selecting the correct solution to meet your specific requirements?
To see the BAUER Nitrogen Systems Brochure
SYSTEM FOOTPRINT
DIMENSIONS L X W X H inches (mm)
Enclosed Design
- 55” x 35” x 70” (1397 mm x 889 mm x 1778 mm)
Open Design
- 54” x 34” x 56” (1397 mm x 864 mm x 1422 mm)
WEIGHT pounds (kg)
Enclosed Design
- 800-1400 lbs (363-635 kg)
Open Design
- 800-900 lbs (363-408 kg)
SOUND LEVEL
(from control panel)
CLOSED DESIGN
- < 76 dbA - < 80 dbA +/- 2 dbA
OPEN DESIGN
- < 90 dbA - < 90 dbA +/- 2 dbA
ACCESSORIES
- High-pressure nitrogen storage assembly (ISO/UN or ASME high-pressure cylinders)
- Crankcase heater with thermostatic control (NEMA1)
- Non-standard voltages and frequencies
- LEAD/LAG alternation
STANDARD SCOPE OF SUPPLY
- 3-, 4-, or 5-Stage BAUER High Pressure Gas Compressor
- High industrial capacity and high flow available
- Output pressures up to 6000 psi
- Turnkey system allows for automated unit shutdown and restart
- Available with Sound Attenuating Enclosure (under 75 dBA) or Open Configuration
- Electric Motor Drive in 50 Hz or 60 Hz, 1 phase and 3 phase
- Air Cooled Intercoolers and Aftercooler
- Inlet Pressure Regulation Systems includes Buffer Tank, Pressure Gauge, Pressure Regulator, Pressure Switch
- UL® Listed Electrical Panel
- PLC Controlled with Touch Screen HMI with readouts for Oil Pressure, Interstage Pressures, Final Pressure, and Hour meter, etc.
- High efficiency dryer and oil removal filter eliminates nitrogen contamination
- Automatic Drains on Interstage and Final Oil / Moisture Separator and Condensate Collection Tank
TECHNICAL DATA
Model | Max Inlet Pressure | Capacity FGD1 | RPM | Number of Stages | Motor | Drive | |||
PSIG | mBAR | SCFM | M3/HR | HP | kW | ||||
UP TO 5000 PSIG OPERATING PRESSURE (LOW INLET PRESSURE) | |||||||||
V*CN100 | 1.5 | 100 | 5 | 8.5 | 1470 | 3 | 5 | 3.7 | E1/E3 |
V*CN120 | 1.5 | 100 | 7.6 | 12.9 | 1470 | 3 | 7.5 | 5.5 | E1/E3 |
V*CN150 | 1.5 | 100 | 18 | 30.5 | 1230 | 4 | 20 | 15 | E3 |
V*CN180 | 1.5 | 100 | 21 | 35.6 | 1320 | 4 | 20 | 15 | E3 |
UP TO 7000 PSIG OPERATING PRESSURE (LOW INLET PRESSURE) | |||||||||
V*CN15.11 | <1 | 50 | 15 | 25.4 | 1320 | 4 | 15 | 11 | E1/E3 |
V*CN18.1 | <1 | 50 | 18 | 30.5 | 1490 | 5 | 20 | 15 | E3 |
UP TO 5000 PSIG OPERATING PRESSURE (ELEVATED INLET PRESSURE) | |||||||||
V*CN12.2 | 75-160 | 5-11 | 7-16.7 | 12-28.5 | 1230 | 2 | 7.5 | 5.5 | E1/E3 |
V*CN15.3 | 101-145 | 7-10 | 18-26.5 | 30.6-45 | 1140 | 2 | 15 | 11 | E3 |
* E = Open Design, A = Enclosed Design ‘1 Volume flow rate according to ISO 1217. Valid for Air and Nitrogen. Capacities for low inlet pressure models referenced to atmospheric inlet pressure. Capacities for elevated inlet pressure models referenced to min. / max. inlet pressure. Motor power valid for max. inlet and final pressure. Actual performance values may vary depending on site conditions.