Need assistance with selecting the correct solution to meet your specific requirements?
To see the entire Breathing Air Brochure
STANDARD SCOPE OF SUPPLY
- BAUER breathing air purification system
- Open vertical cabinet made of formed sheet steel providing a firm foundation for all pressure bearing components
- Modern design with unsurpassed maintenance accessibility (no hand tools are required for normal maintenance checks and fluid level confirmation)
- BAUER PLC based controller with four-line text display
- Self adjusting drive belt tensioner
- NEMA 4 rated electrical enclosure with UL® listed control panel
- All wiring harnesses incorporated within a corrugated loom with number coding for easy system diagnosis
- Emergency stop push button
- Stainless steel tubing throughout, no cheap plastic tubing
- Rugged powder coat finish
- Automatic condensate drain system with integral reservoir level sensor to provide system shutdown when the reservoir is full
- Interstage pressure gauges (locally mounted)
- SECURUS Moisture Monitor
SYSTEM FOOTPRINT
DIMENSIONS L x W x H inches (mm)
- 44” x 33” x 54” (1118 mm x 838 mm x 1372 mm)
WEIGHT pounds (kg)
- 1075 lbs (488 kg)
PLC CONTROLLER
- Compressor on/off, final pressure, oil pressure, high temperature shutdown
- Supports automatic condensate drain system
- Motor overload indication
- Final separator counter with shutdown and operator indication
TECHNICAL DATA
Model | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
CFS5.5®-3S | Three position CFS equipped with inlet pressure gauge adjustable regulator, regulated pressure gauge, fill control valve, and fill pressure gauges. Unit will consist of dual function, top mount, four (4) bank cascade panel. The dual function feature offers the ability to refill a storage bank, even with the bank valve closed, while filling SCBAs from another bank. It also includes an air direction valve allowing the operator to select “fill from storage” or “fill from compressor.” Additionally, the system includes a regulated remote fill outlet. |
||||||||
CFS5.5®-2S | Two position CFS equipped with inlet pressure gauge adjustable regulator, regulated pressure gauge, fill control valve and fill pressure gauges. Unit will consist of dual function, top mount, four (4) bank cascade panel. The dual function feature offers the ability to refill a storage bank, even with the bank valve closed, while filling SCBAs from another bank. It also includes an air direction valve allowing the operator to select “fill from storage” or “fill from compressor." Additionally, the system includes a regulated remote fill outlet. |